IDA (Interdigitated Array) Electrode 10 µm
Genaral configuration for the IDA electrode:

Cyclic Voltammetry Measurement using IDA Electrode

Interdigitated 65 pairs of generator / collector electrodes set off electrochemical RedOx cycling continuously as shown in Fig. 1. This reaction significantly boosts sensitivity of the electrode. Furthermore, samples are preserved when Dual (Red-Ox) Mode is chosen - Not like as Single Mode eats up samples at measurements.
| Catalog No. | Description | Width (µm) | Interval (µm) | Length (mm) | Number of feet (pairs) |
| 012125 | IDA electrode (Au) | 10 | 5 | 2 | 65 |
| 012126 | IDA electrode (Pt) | 10 | 5 | 2 | 65 |
| 012127 | IDA electrode (Carbon) | 10 | 5 | 2 | 65 |
| 012128 | IDA electrode (ITO) | 10 | 5 | 2 | 65 |
New product line without passivation membrane
| Catalog No. | Description | Width (µm) | Interval (µm) | Length (mm) | Number of feet (pairs) |
| 012259 |
IDA electrode (Au) without passivation membrane |
10 | 5 | 2 | 65 |
| 012262 |
IDA electrode (Pt) without passivation membrane |
10 | 5 | 2 | 65 |
| 012265 |
IDA electrode (ITO) without passivation membrane |
10 | 5 | 2 | 65 |
| 012266 |
IDA electrode (Carbon) without passivation membrane |
10 | 5 | 2 | 65 |
IDA Electrode Connecting Cable kit
This device is used as a substituting item of a connecting part of IDA Electrode.
| Catalog No. | Description |
| 011066 | Cable kit for IDA electrode |
| Components | |
| Connecting Cable | |
| Electrode fixer | |
| Mini-Vice | |
Please treat IDA Electrodes with care especially when you insert and remove them since it consists of quartz glass.
If you had a difficulty in setting up of an IDA Electrode into a connector at the cable, loosening the four grippers of the connector (shown in Figure below) with a tweezer would work.

Figure in right shows wire assembly of connecting cable.
In order to avoid abrasion on a connector part of the electrode, please insert and remove it according to the following order:
[IDA Electrode Setup Sequence]
(1)Put the IDA electrode into the connector (2)Insert the white color electrode fixer into the connector
[IDA Electrode Remove Sequence]
(1)Remove the white color electrode fixer from the connector (2)Remove the IDA electrode from the connector
New Product
New width in the product line, and you could have 2 µm IDA with or without passivation membrane.
| Catalog No. | Description | Width (µm) | Interval (µm) | Length (mm) | Number of feet (pairs) |
| 012257 | IDA electrode (Au) | 2 | 2 | 2 | 65 |
| 012258 | IDA electrode (Pt) | 2 | 2 | 2 | 65 |
| 012261 |
IDA electrode (Au) without passivation membrane |
2 | 2 | 2 | 65 |
| 012264 |
IDA electrode (Pt) without passivation membrane |
2 | 2 | 2 | 65 |