SEC2000 UV/VIS Application
SEC2000-UV/VIS Spectrometer is simple and easy operation, compact and multi-channel spectrometer. In the light source the lens was incorporated to the light in a small module, it eliminated the need of fiber optics (Fig. 1). The main application of SEC2000 is for spectroelectrochemical measurements. Moreover, the combination with fiber-optics probe, introduced below, becomes possible the application in a wide experimental fields.
Based on the examples below, you could find your own configuration!

⇒Features
・Three measurement modes in one
(Absorbance/Reflectance/Irradiance)
・Real-time measurement
・Quantitative/Calibration mode
・Quickly analysis
・Portable
⇒Specifications
・Wavelength range: 200 nm ∼ 900 nm
or 400 ∼ 1000 nm
・Resolution: ∼ 2.3 nm
・Dark noise: < 2 mAbs
Example of experimental configuration
Spectroelectrochemical measurement
ALS1200A Electrochemical analyzer and SEC-C Thin Layer Quartz Glass Spectroelectrochemical cell combination could be a compact configuration for spectroelectrochemical measurement. The oxidation of Potassium Ferrycianide at 800 mV vs Ag/AgCl was measured by absorbance mode using SEC2000 (Fig.2).
Fig.2 Spectroelectrochemical measurement system and Spectrogram.
Combination with fiber optics
When you connect the optional fiber optics in SEC2000 Spectrometer, it could amplify the experimental application field. Some of the configurations are shown below.
Example 1 Reflection spectra measurement using reflection probe |
Example 2 Reflection spectra measurement using reflection probe for immersion |
![]() |
![]() |
Color analysis and absorbance of the material could be measured by reflected light spectrum. Fiber optic from light source and detector is embedded in a reflection light measured probe. | Measurement using immersion probe could be directly with the immersion of the probe in a sample, without any previous adjustment. |
Example 3 Fluorescence measurements using UV-LED light source |
Example 4 Relative radiation light measurement |
![]() |
![]() |
With an absolute spectral intensity irradiation at 90 degrees, the fluorescence of the sample could be measured. For this application a high power supply, as LED power supply, is recommended. | Radiation, as a solar radiation, with a 180 degrees field of view, could be collected using Cosine Correctors at the extremity of the fiber optic connected to the SEC2000-UV/VIS. |
SEC2000 - Combo kit
Catalog No. | Description |
013253 | SEC2000-UV/VIS Spectrometer combo Kit Ver.1.3 |
Components | |
013256 | SEC2000-UV/VIS Spectrometer Ver1.3 SLIT50 |
012193 | SEC2000-DH UV Light Source |
012195 | SEC2000-CUV Cuvette Holder |
Catalog No. | Description |
013250 | SEC2000-VIS/NIR Spectrometer combo Kit Ver.1.3 |
Components | |
013251 | SEC2000-VIS/NIR Spectrometer Ver.1.3 SLIT50 |
012194 | SEC2000-TH Visible Light Source |
012244 | SEC2000-CUV Cuvette Holder with diffusion plate |